: The unit typically uses a brown wire (terminal 11) and a white wire (terminal 12) for connection.
The Simrad RF300 features a standard two-wire frequency-modulated output signal (unpolarized). It connects directly to the rudder feedback input on compatible Simrad autopilot computers (such as the AC10, AC20, AC40, or Robnet series). RF300 Wire Color Autopilot Computer Terminal Rudder / Feedback Input (Positive/Signal) White Rudder / Feedback Input (Negative/Return) Wiring Best Practices simrad rf300 installation manual
Locate a flat, rigid structural member or bulkhead near the rudder quadrant or tiller arm. Place the RF300 unit on the mounting surface. : The unit typically uses a brown wire
Once mechanically and electrically installed, the system must be calibrated through your Simrad autopilot control head (e.g., AP24, AP44, or an NSS/NSX/NSO multifunction display). or an NSS/NSX/NSO multifunction display).